Calculadora de Figura de Ruido Gratis

Calcula la figura de ruido de amplificadores y receptores RF para evaluar la sensibilidad del sistema.

dB
dB
dB
dB
dB

Cascaded Noise Figure

1.80 dB

Ganancia Total35.0 dB
Noise Temperature148.5 K

Cascaded Noise Figure vs Stage 1 Noise Figure

Fórmula

## Friis Noise Figure Formula ### Formula **F_total = F1 + (F2 - 1)/G1 + (F3 - 1)/(G1 x G2) + ...** All values in linear (not dB). The first stage dominates overall noise figure. Use a low-noise amplifier (LNA) first for best sensitivity.

Ejemplo Resuelto

LNA (1.5 dB NF, 20 dB gain) followed by mixer (10 dB NF, 15 dB gain) and IF amp (15 dB NF).

  1. 01F1 = 10^(1.5/10) = 1.413
  2. 02F2 = 10^(10/10) = 10, G1 = 10^(20/10) = 100
  3. 03F3 = 10^(15/10) = 31.62, G2 = 10^(15/10) = 31.62
  4. 04F_total = 1.413 + (10-1)/100 + (31.62-1)/(100x31.62) = 1.413 + 0.09 + 0.0097 = 1.513
  5. 05NF = 10 x log10(1.513) = 1.80 dB

Preguntas Frecuentes

Why is the first stage so important?

Noise from later stages is divided by the gain of preceding stages. High first-stage gain makes subsequent noise negligible.

What is a good LNA noise figure?

Below 1 dB for satellite receivers. 1-3 dB for typical RF systems. Above 3 dB is considered noisy.

Loss before the LNA?

Any loss (cable, filter) before the LNA adds directly to the noise figure. A 3 dB cable loss adds 3 dB to system NF.

Aprender

Ohm's Law Guide

Calculadoras Relacionadas