Calculadora de Capacitor de Desacople — Fórmula
## Decoupling Capacitor Sizing
### Formula
**C = I x dt / dV**
Where I is the transient current, dt is the duration of the transient, and dV is the maximum allowed voltage droop. Place decoupling caps as close to the IC power pins as possible.
### Formula
**C = I x dt / dV**
Where I is the transient current, dt is the duration of the transient, and dV is the maximum allowed voltage droop. Place decoupling caps as close to the IC power pins as possible.
Ejemplo Resuelto
0.5 A transient for 10 us, maximum 100 mV droop.
- dt = 10 / 1000000 = 0.00001 s
- dV = 100 / 1000 = 0.1 V
- C = 0.5 x 0.00001 / 0.1 = 0.00005 F = 50 uF