Calculateur de Colonne en Béton Gratuit

Dimensionnez une colonne en béton armé. Calculez les dimensions, le ferraillage et le volume de béton nécessaires.

in
in
ft

Concrete Volume

0.37 cu yd

Concrete Volume10.0 cu ft
Total Rebar Length48 ft

Concrete Volume vs Width / Diameter

Formule

Concrete Column Volume

Rectangular: V = W x D x H

Round: V = pi x (D/2) squared x H

Convert all dimensions to consistent units. Add 2 ft per bar for lap splices and embedment into the footing. Vertical rebar count must be at least 4 for rectangular columns and 6 for round columns per ACI 318.

Exemple Résolu

12 x 12 in rectangular column, 10 ft tall, 4 bars.

  1. 01Area = 12 x 12 = 144 sq in = 1 sq ft
  2. 02Volume = 1 x 10 = 10 cu ft = 0.37 cu yd
  3. 03Rebar = 4 x (10 + 2) = 48 ft

Questions Fréquentes

What is the minimum reinforcement for a concrete column?

ACI 318 requires a minimum of 1% of the gross cross-section area in vertical reinforcement and a maximum of 8%. Ties or spirals provide lateral confinement.

How are ties spaced on a concrete column?

Standard tie spacing is the smallest of: 16 bar diameters, 48 tie diameters, or the least column dimension. Typical residential columns use No. 3 ties at 12 inches on center.