Calculateur de Charge de Colonne Gratuit
Calculez la capacité de charge d'une colonne structurelle. Déterminez la charge admissible selon les dimensions et le matériau.
Maximum Load
36,000 lbs
Maximum Load vs Column Width
Formule
Column Axial Load
P = A x Fc
Where A is the cross-sectional area and Fc is the allowable compressive stress. This applies to short columns where buckling is not a concern. For slender columns, the Euler buckling formula must be used to reduce the allowable load.
Exemple Résolu
6x6 wood column with 1,000 psi allowable stress.
- 01Area = 6 x 6 = 36 sq in
- 02Max load = 36 x 1000 = 36,000 lbs = 36 kips
- 03Note: actual lumber is 5.5 x 5.5 so use 30.25 sq in.
Questions Fréquentes
When is a column considered short vs slender?
For wood, if the slenderness ratio (Le/d) is less than about 11, it is a short column. Steel columns use KL/r; below about 40 is considered short. Slender columns require buckling analysis.
What is the actual size of a 6x6 post?
Nominal 6x6 lumber actually measures 5.5 x 5.5 inches. Always use the actual dimensions for structural calculations.