Calculadora de Factor de Capacidad Gratis

Calcula el factor de capacidad comparando producción real con la máxima teórica de la planta.

MWh
MW
hours

Capacity Factor

14.3 %

Maximum Possible Output17,520 MWh
Unused Capacity15,020 MWh

Capacity Factor vs Time Period

Fórmula

## Power Plant Capacity Factor The capacity factor measures how much energy a plant actually produces compared to its theoretical maximum if it ran at full power continuously. ### Formula **Capacity Factor = Actual Output / (Rated Capacity x Hours) x 100%** Typical capacity factors: Nuclear 90-93%, Natural gas 40-60%, Wind onshore 25-45%, Solar PV 15-30%. Higher factors mean better utilization of installed capacity.

Ejemplo Resuelto

A 2 MW wind turbine produces 2,500 MWh in one year (8,760 hours).

  1. 01Maximum output = 2 MW x 8,760 hr = 17,520 MWh
  2. 02Capacity factor = 2,500 / 17,520 x 100 = 14.3%
  3. 03Unused capacity = 17,520 - 2,500 = 15,020 MWh

Preguntas Frecuentes

Why is solar capacity factor so low?

Solar panels only generate power during daylight and output varies with clouds and seasons. A 25% capacity factor means the panels average one quarter of their peak rating.

Does a low capacity factor mean the plant is inefficient?

Not necessarily. Wind and solar have low capacity factors due to weather variability, not mechanical inefficiency. The metric reflects resource availability.

Can capacity factor exceed 100%?

In rare cases, a plant may briefly exceed its nameplate rating under favorable conditions, but sustained capacity factors above 100% are not possible.