Calculadora de Sobreoscilación Gratis

Calcula el porcentaje de sobreoscilación máxima de un sistema subamortiguado a partir de la relación de amortiguamiento.

rad/s

Percent Overshoot

37.23 %

Peak Time0.3293 s
Damped Frequency9.539 rad/s

Percent Overshoot vs Damping Ratio (zeta)

Fórmula

## Second-Order Overshoot Overshoot is the amount by which the step response exceeds the final steady-state value, expressed as a percentage. It depends only on the damping ratio. ### Formula **%OS = 100 × exp(-pi × zeta / sqrt(1 - zeta²))** **Peak time: tp = pi / omega_d**, where omega_d = omega_n × sqrt(1 - zeta²) is the damped natural frequency. For zeta = 0 (undamped), overshoot is 100%. For zeta >= 1 (critically damped or overdamped), there is no overshoot.

Ejemplo Resuelto

A system with zeta = 0.3, omega_n = 10 rad/s.

  1. 01omega_d = 10 × sqrt(1 - 0.09) = 10 × 0.9539 = 9.539 rad/s
  2. 02%OS = 100 × exp(-pi × 0.3 / 0.9539)
  3. 03%OS = 100 × exp(-0.9874) = 100 × 0.3730 = 37.30%
  4. 04Peak time = pi / 9.539 = 0.3293 s

Preguntas Frecuentes

What damping ratio gives 5% overshoot?

Setting %OS = 5 and solving: zeta = -ln(0.05) / sqrt(pi² + ln²(0.05)) = 2.996 / sqrt(9.870 + 8.976) = 2.996 / 4.340 = 0.690. So zeta ≈ 0.69 gives about 5% overshoot.

Can overshoot be eliminated?

Yes, by making zeta >= 1 (critically or over-damped). However, this makes the system slower. In practice, designers often accept 5-10% overshoot for faster response (zeta ≈ 0.6-0.8).

Is overshoot always bad?

Not always. Some systems (like position servos) may tolerate small overshoot if it means faster response. But for processes like temperature control or chemical dosing, any overshoot can be harmful or dangerous.