Calculadora de Pérdida de Calor Gratis

Calcula la pérdida de calor de un edificio para dimensionar correctamente el sistema de calefacción.

sq ft
degF

Total Heat Loss (with infiltration)

11,538 BTU/hr

Conductive Loss9,615 BTU/hr
Estimated Furnace Size20,000 BTU/hr

Total Heat Loss (with infiltration) vs Envelope Area (walls + ceiling)

Fórmula

Building Heat Loss

Q = (A / R) x DeltaT x Infiltration Factor

A is the total building envelope area through which heat escapes, R is the insulation R-value, and DeltaT is the temperature difference between inside and outside. The infiltration factor (1.1 to 1.5) adds losses from air leakage.

Ejemplo Resuelto

2,500 sq ft envelope, R-13, 50 degF difference, 1.2 infiltration.

  1. 01Conductive = 2500 / 13 x 50 = 9,615 BTU/hr
  2. 02With infiltration = 9,615 x 1.2 = 11,538 BTU/hr
  3. 03Furnace size = round up to 20,000 BTU/hr

Preguntas Frecuentes

What is a typical design temperature difference?

Use the outdoor design temperature for your area (available from ASHRAE data) subtracted from your desired indoor temperature (usually 70 degF). For example, if outdoor design is 5 degF, DeltaT = 65.

Should windows be calculated separately?

For accuracy, yes. Windows have much lower R-values (R-1 for single pane, R-3 for double). Calculate window and wall areas separately and sum the losses.