Kostenloser Treppenwange-Rechner
Berechnen Sie Stufenhöhe, Auftrittstiefe und Wangenlänge für Ihren Treppenbau.
Vertical distance from finished floor to finished floor
Code max is typically 7-3/4 inches
Code minimum is typically 10 inches
Number of Risers
14
Number of Risers vs Total Rise (Floor to Floor)
Formel
## How to Calculate Stair Stringers ### Formula **Number of Risers = round(Total Rise / Desired Riser Height)** **Actual Riser = Total Rise / Number of Risers** **Number of Treads = Number of Risers - 1** **Total Run = Number of Treads × Tread Depth** **Stringer Length = sqrt(Total Rise² + Total Run²)** Building code typically requires: Max riser height 7-3/4 inches, min tread depth 10 inches, and the riser + tread combination should fall between 17 and 18 inches.
Lösungsbeispiel
A staircase with 108 inches (9 feet) of total rise, 7.5" desired risers, 10" treads, 36" wide.
- 01Number of risers = round(108 / 7.5) = 14 risers
- 02Actual riser height = 108 / 14 = 7.714 inches
- 03Number of treads = 14 - 1 = 13 treads
- 04Total run = 13 × 10 = 130 inches (10.83 ft)
- 05Stringer length = sqrt(108² + 130²) = sqrt(28,564) = 169 inches (14.1 ft)
- 06Stringers needed = 3 (for 36" width)
Häufig Gestellte Fragen
What is the maximum riser height allowed by code?
The IRC (International Residential Code) limits risers to 7-3/4 inches maximum. Local codes may vary. All risers in a flight must be uniform (within 3/8 inch).
What is the minimum tread depth?
The IRC requires a minimum tread depth of 10 inches (not including the nosing). The nosing should project 3/4 to 1-1/4 inches beyond the riser.
How many stringers do I need?
Use 3 stringers for stairs up to 36 inches wide. Add an additional stringer for every 16 inches of width beyond 36 inches.
Lernen