Kostenloser Notstromaggregat-Rechner

Dimensionieren Sie ein Notstromaggregat durch Berechnung von Dauer- und Anlaufleistung.

W
W
x

Minimum Generator Size

9.0 kW

Running Load5.0 kW
Starting Surge4.0 kW

Minimum Generator Size vs Total Running Watts

Formel

## Generator Sizing **Minimum kW = Running Watts + Starting Surge** Motors (AC units, pumps, refrigerators) draw 2 to 6 times their running watts during startup. Add the surplus starting watts of the largest motor to the total running watts of everything else.

Lösungsbeispiel

5,000W running load, largest motor is 2,000W with 3x starting surge.

  1. 01Running = 5,000W
  2. 02Surge = 2,000 x 3 - 2,000 = 4,000W extra
  3. 03Total = 5,000 + 4,000 = 9,000W = 9.0 kW
  4. 04Select a 10 kW generator.

Häufig Gestellte Fragen

What appliances have the highest starting surge?

Central AC units (3-5x), well pumps (3-5x), and sump pumps (2-3x) have the highest starting surges. Resistive loads like heaters and lights have no surge.

Should I size for the whole house?

A whole-house generator typically needs 15-25 kW. For a portable backup, prioritize essential circuits (fridge, sump pump, furnace, lights) and size accordingly.