Calculadora de Figura de Ruído

Calcule a figura de ruído de componentes e sistemas de RF para otimizar a sensibilidade do receptor.

dB
dB
dB
dB
dB

Cascaded Noise Figure

1.80 dB

Ganho Total35.0 dB
Noise Temperature148.5 K

Cascaded Noise Figure vs Stage 1 Noise Figure

Formula

## Friis Noise Figure Formula ### Formula **F_total = F1 + (F2 - 1)/G1 + (F3 - 1)/(G1 x G2) + ...** All values in linear (not dB). The first stage dominates overall noise figure. Use a low-noise amplifier (LNA) first for best sensitivity.

Exemplo Resolvido

LNA (1.5 dB NF, 20 dB gain) followed by mixer (10 dB NF, 15 dB gain) and IF amp (15 dB NF).

  1. 01F1 = 10^(1.5/10) = 1.413
  2. 02F2 = 10^(10/10) = 10, G1 = 10^(20/10) = 100
  3. 03F3 = 10^(15/10) = 31.62, G2 = 10^(15/10) = 31.62
  4. 04F_total = 1.413 + (10-1)/100 + (31.62-1)/(100x31.62) = 1.413 + 0.09 + 0.0097 = 1.513
  5. 05NF = 10 x log10(1.513) = 1.80 dB

Perguntas Frequentes

Why is the first stage so important?

Noise from later stages is divided by the gain of preceding stages. High first-stage gain makes subsequent noise negligible.

What is a good LNA noise figure?

Below 1 dB for satellite receivers. 1-3 dB for typical RF systems. Above 3 dB is considered noisy.

Loss before the LNA?

Any loss (cable, filter) before the LNA adds directly to the noise figure. A 3 dB cable loss adds 3 dB to system NF.