Calculadora de Timer 555 Monoestável — Formula
## 555 Timer Monostable Mode
### Formula
**T = 1.1 x R x C**
A trigger pulse starts timing. The output goes high for time T then returns low. The circuit requires a new trigger for each pulse.
### Formula
**T = 1.1 x R x C**
A trigger pulse starts timing. The output goes high for time T then returns low. The circuit requires a new trigger for each pulse.
Exemplo Resolvido
R = 100k, C = 10 uF.
- T = 1.1 x 100000 x 0.00001
- T = 1.1 seconds
- T = 1100 ms