Calcolatore Riduzione del Rumore

Calcola l'attenuazione del rumore con barriere acustiche e materiali fonoassorbenti.

dB
m2
m2 Sabine

Noise Reduction

48.01 dB

Noise Reduction vs Transmission Loss (TL)

Formula

Noise Reduction Between Rooms

The noise reduction (NR) is the actual level difference between two rooms separated by a partition.

Formula

NR = TL + 10 log10(A / S)

  • *TL* = sound transmission loss of the wall (dB)
  • *A* = total absorption in the receiving room (Sabine)
  • *S* = area of the partition
  • If the receiving room is very absorbent (A > S), NR exceeds TL. If it is reverberant (A < S), NR is less than TL.

    Esempio Risolto

    Wall TL = 45 dB, wall area = 15 m2, receiving room absorption = 30 m2 Sabine.

    1. 01NR = TL + 10 log10(A/S)
    2. 02NR = 45 + 10 log10(30/15)
    3. 03NR = 45 + 10 log10(2)
    4. 04NR = 45 + 3.01 = 48.01 dB

    Domande Frequenti

    What is transmission loss?

    TL measures how well a partition blocks sound. It is the ratio of incident to transmitted power in dB. A concrete wall might have TL = 50 dB; a thin plasterboard wall about 25 dB.

    Why does receiving room absorption matter?

    Sound that enters the receiving room reverberates. More absorption means the energy dissipates quickly, lowering the steady-state level and increasing effective NR.

    How do I improve noise reduction?

    Increase the wall TL (thicker, denser, or double-leaf walls) and increase absorption in the receiving room (acoustic panels, carpet).