Calcolatore Portata Fognaria Gratuito

Stima la portata delle acque reflue in base al numero di utenti e alle unità di carico.

people
gal/day

Average Daily Flow

4,000 gal/day

Peak Hourly Flow417 gal/hr
Peak Minute Flow6.9 GPM

Average Daily Flow vs Number of Occupants

Formula

## Sewage Flow Estimation **Average Daily Flow = Occupants x Per Capita GPD** **Peak Flow = Average / 24 x Peak Factor** Residential per-capita wastewater is typically 60 to 100 gallons per day. The peak-hour factor (2 to 4 for residential, up to 5 for commercial) accounts for the morning and evening surges.

Esempio Risolto

50 occupants, 80 gal/day each, peak factor 2.5.

  1. 01Avg daily = 50 x 80 = 4,000 gal/day
  2. 02Avg hourly = 4,000 / 24 = 167 gal/hr
  3. 03Peak hourly = 167 x 2.5 = 417 gal/hr
  4. 04Peak GPM = 417 / 60 = 6.9 GPM

Domande Frequenti

What per-capita flow should I assume?

Residential: 60 to 100 GPD. Office buildings: 15 to 25 GPD per worker. Schools: 10 to 15 GPD per student. Restaurants: 30 to 50 GPD per seat.

Why use a peak factor?

Sewage flow is not constant throughout the day. The peak factor ensures the system can handle the busiest hour without backing up.

Impara

How to Calculate Concrete Needed for Any Project

Calcolatrici Correlate