Calcolatore Plinto di FondazioneFormula

## Footing Sizing

**Footing Area = Total Load / Soil Bearing Capacity**

The bearing capacity depends on soil type: soft clay 1,000 psf, medium clay/loose sand 2,000 psf, dense sand/gravel 3,000-4,000 psf, bedrock 8,000+ psf. Always get a soil test for structural footings.

Esempio Risolto

20,000 lb column load on soil with 2,000 psf bearing.

  1. Area = 20,000 / 2,000 = 10 sq ft
  2. Square footing = sqrt(10) = 3.16 ft per side
  3. Use a 3.5 x 3.5 ft footing (12.25 sq ft) for safety.