## L-Network Impedance Matching

**Q = sqrt(R_high/R_low - 1)**

**X_series = Q x R_low**

**X_shunt = R_high / Q**

Choose series inductor + shunt capacitor, or vice versa, to realize the reactance values at the operating frequency.

हल किया गया उदाहरण

Match 50 ohms to 200 ohms at 100 MHz.

  1. Q = sqrt(200/50 - 1) = sqrt(3) = 1.732
  2. X_series = 1.732 x 50 = 86.6 ohms
  3. X_shunt = 200 / 1.732 = 115.5 ohms