Column Buckling Calculator

Find the critical buckling load of a column using the Euler buckling equation.

GPa
cm^4
m

Euler Critical Load (Pcr)

1,233.7 kN

Effective Length4.00 m

Euler Critical Load (Pcr) vs Elastic Modulus (E)

Formule

## Euler Column Buckling A slender column under axial compression can buckle laterally before the material yields. ### Formula **Pcr = pi^2 E I / (K L)^2** K is the effective length factor that accounts for end conditions: K = 1.0 for pinned-pinned, K = 0.7 for fixed-pinned, K = 0.5 for fixed-fixed, and K = 2.0 for fixed-free (cantilever). The formula assumes perfectly straight, elastic behaviour.

Exemple Résolu

A 4 m pinned-pinned steel column with I = 1000 cm^4 and E = 200 GPa.

  1. 01Effective length Le = 1.0 x 4 = 4 m
  2. 02E = 200 x 10^9 Pa, I = 1000 x 10^-8 m^4 = 1 x 10^-5 m^4
  3. 03Pcr = pi^2 x 200 x 10^9 x 1 x 10^-5 / 4^2
  4. 04Pcr = 9.8696 x 2 x 10^6 / 16 = 1,233,700 N = 1233.7 kN

Questions Fréquentes

What does the K factor represent?

K adjusts the physical length to an effective length based on how the column ends are restrained. Pinned-pinned is K=1, fixed-fixed is K=0.5, fixed-pinned is K=0.7, and cantilever is K=2.

When does Euler buckling not apply?

Euler buckling applies only to long, slender columns where failure is elastic. For short, stocky columns the material yields before buckling, and inelastic buckling formulas or direct strength checks are needed.

How do I find the moment of inertia for standard sections?

Steel section property tables (such as the AISC Steel Manual or equivalent) list I values for all standard W, HSS, and channel shapes.