Calculateur de Fréquence de Nyquist — Formule
Decoupling Capacitor Sizing
Formula
C = I x dt / dV
Where I is the transient current, dt is the duration of the transient, and dV is the maximum allowed voltage droop. Place decoupling caps as close to the IC power pins as possible.
Exemple Résolu
0.5 A transient for 10 us, maximum 100 mV droop.
- dt = 10 / 1000000 = 0.00001 s
- dV = 100 / 1000 = 0.1 V
- C = 0.5 x 0.00001 / 0.1 = 0.00005 F = 50 uF