Op-Amp Bandwidth Calculator

Calculate closed-loop bandwidth of an op-amp circuit from its gain-bandwidth product and gain setting.

MHz
V/V

Closed-Loop Bandwidth

100.0 kHz

Bandwidth (Hz)100,000 Hz
Gain (dB)20.00 dB

Closed-Loop Bandwidth vs Gain-Bandwidth Product

Op-Amp Gain-Bandwidth Product

Formula

BW = GBW / A_CL

Where GBW is the gain-bandwidth product and A_CL is the closed-loop gain. Higher gain means lower bandwidth. This is a fundamental trade-off in op-amp circuits.

Example Calculation

An op-amp with GBW = 1 MHz set to a gain of 10.

  1. 01BW = 1 MHz / 10 = 100 kHz
  2. 02BW in Hz = 1,000,000 / 10 = 100,000 Hz
  3. 03Gain in dB = 20 x log10(10) = 20 dB

Frequently Asked Questions